DRILLING / Lost Circulation Solutions

LCP 2000®

Lost Circulation Solution for Severe to Total Losses

LCP 2000® is a proven lost circulation solution that can be used as an additive to drilling, workover and completion fluids. This advanced LCM (lost circulation material) is designed to cure partial to total losses. LCP 2000 has been utilized successfully in hundreds of challenging wells around the world to cure severe losses. It is non-damaging in reservoirs and works in high-pressure, high-temperature (HPHT) wells. LCP 2000 is operationally friendly; one sack can be added as an LCM pill at 25-50 ppb in WBM and up to 100 ppb in OBM. LCP 2000’s particle size eliminates the risk of plugging mud motors, MWD/LWD tools and bit nozzles.

LCP 2000 is a selected blend of organic flakes, fibers and inorganic granules. Its primary use is as a lost circulation pill for severe to total losses for induced and natural fractures, faults and small vugs. It can be used as an LCM pill with any fluid system. LCP 2000 can be used to treat seepage as well as partial, severe and total losses.

Product Specifications

LCP 2000® Specifications

Applications
  • Designed for drilling, workover and completion fluids
  • Compatible with all common fluid systems
  • High to total loss rates
Advantages
  • Passes EPA LC50 test, Category E rated by CEFAS
  • Pill can be pumped through downhole equipment, removing need to trip prior to treatment
  • Properly prepared and placed pill will hold >1,000 psi differential, once healed
  • No negative effects on mud properties
  • Readily available
Environmental Advantage
  • LCP 2000 is environmentally compliant for use in all areas
  • PLONOR listed for North Sea use, HMCS Category P, OCNS Group E
  • Passes the North America 96-hr LC50 bioassay mysid shrimp
Close
LCP 2000®
LCP 2000®

LCP 2000® Specifications

Applications
  • Designed for drilling, workover and completion fluids
  • Compatible with all common fluid systems
  • High to total loss rates
Advantages
  • Passes EPA LC50 test, Category E rated by CEFAS
  • Pill can be pumped through downhole equipment, removing need to trip prior to treatment
  • Properly prepared and placed pill will hold >1,000 psi differential, once healed
  • No negative effects on mud properties
  • Readily available
Environmental Advantage
  • LCP 2000 is environmentally compliant for use in all areas
  • PLONOR listed for North Sea use, HMCS Category P, OCNS Group E
  • Passes the North America 96-hr LC50 bioassay mysid shrimp